Design & Functionality:
The new Samsung AR4500 range with Digital inverter saves money by constantly maintaining pre-set temperature without constantly switching on and off. Cooling capacities rom 2.50kW up to 6.45kW, heating rom 2.6kW up to 6.5kW. EERs (Cooling W/W) are rom 3.01 up to 3.21 and COPs <Heating W/W) up to 3.55. Piping lenghts (indoor/outdoor) are 15 to 25 meters, with a height difference 0 10meters.
Capacity:
Capacity (Cooling, Btu/hr): 22008 Btu/hr
Capacity (Heating, Btu/hr): 23032 Btu/hr
Capacity (Cooling, Min – Max, Btu/hr): 5,800 – 25,200 Btu/hr
Capacity (Heating, Min-Max, Btu/hr): 4,800 – 27,000 Btu/hr
Capacity (Cooling, kW): 6.45kW
Capacity (Heating, kW): 6.75kW
Capacity (Cooling, Min-Max, kW): 1.70-7.40kW
Capacity (Heating, Min-Max,kW): 1.40-7.90kW
Energy Efficiency:
EER (Cooling,W/W): 3.21W/W
COP (Heating, W/W): 3.55W/W
EER (Cooling, Btu/hW): 10.95 Btu/hW
COP (Heating, Btu/hW): 12.12 Btu/hW
Noise Level:
Noise Level (Indoor, High/Low, dBA): 46/37 dBA
Noise Level (Outdoor, High/Low, dBA): 54 dBA
Electrical Data:
Power Source(Φ/V/Hz): 1 / 220∼240 / 50
Power Consumption (Cooling, W): 2010W
Power Consumption (Heating, W): 1900W
Operating Current (Cooling,A): 9.00A
Operating Current (Heating, A): 8.50A
Technical Information:
Piping Lenght (Max, m): 25m
Piping Height (Max, m): 10m
SVC Valve (Liquid (0DxL)): Φ6
SVC Valve (Gas (0Dxl)): Φ16
Moisture Removal (I/hr): 2.00I/hr
Air Circulation (Cooling, ºC): 1200ºC/min
Refrigerant (Type): R410A
Low Ambient (Cooling, ºC): 18 ∼ 48ºC
Low Ambient (Heating, ºC): -7∼24ºC
Air Flow
Air Direction Control (Up/Down): Auto
Air Direction Control (Left/Right): Manual
Air Flow Control Step (Cool/Fan): 3 Step
Convenience:
Indoor Temp. Display: Yes
Display On/Off: Yes
24-Hour Timer: Yes
Auto Restart: Yes
Operating Mode:
Auto Mode: Yes
Fast Cool: Yes
Good Sleep: Yes
Dehumidification: Yes
Fan Mode: Yes
Due to Samsung’s policy of constant improvement, specifications are subject to change without notice. E&OE.
- Specifications may be subject to change without prior notice.
- 1) Cooling capacities are base on; – Indoor temperature: 27ºC DB, 19ºC WB – Outdoor temperature: 35ºC DB, 24ºC WB, Equivalent refrigerant piping: 5m, Level differences: 0m
- 2) Heating capacities are based on: – Indoor temperature: 20ºC DB, 15ºC WB – Outdoor temperature: 7ºC DB, 6ºC WB, Equivalent refrigerant piping: 5m, Level differences: 0m
- 3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.
- 4) These products contain R410A which is fluorinated greenhouse gas.